Choose your boiler HP to display system specs. Boiler feed and condensate return systems are typically assembled to order. Standard lead time is 1–2 weeks before shipment. Lead times may vary depending on pump availability, as pump inventory fluctuates. If lead times change, we will notify you promptly.

Description

BJHV-7 Vertical 11 Gauge Steel Condensate Return System for 40–50 Boiler HP

The BJHV-7 vertical 11 gauge steel condensate return system is built for boiler applications that need added receiver capacity and dependable pump performance in a vertical layout. This unit includes an 18" diameter x 48" high 11 gauge steel vertical receiver tank, mounted stand, float assembly, gauge glass, and a factory-plumbed Burks pump package.

Designed for boilers from 40 to 50 HP, this ready-to-install system provides more receiver volume than the 18" x 42" vertical model while keeping a compact floor footprint. The heavy-duty steel tank provides strength and longevity, while the mounted pump and pre-piped assembly reduce installation time in the field.

Need a tank-only replacement later? View the matching 18 x 48 vertical steel replacement return tank. Need a different size, control arrangement, or voltage? View our custom work options or browse all condensate return systems.

Rema Dri-Vac Model
BJHV-7
Boiler Range: 40–50 HP
Tank Size: 18" Dia. x 48" High
Tank Capacity: 52 Gallons
Tank Material: 11 Gauge Steel
Pump Options: Burks 20CS6M or 320CS6M
Float Options: 1/2" or 3/4" Float Assembly

Download System Drawing
Learn About Return Systems

What Is Included

  • 18" diameter x 48" high vertical receiver tank in 11 gauge steel
  • Mounted stand
  • Float assembly option: 1/2" or 3/4" float assembly
  • Brass float valve, brass rod, and 5" copper float ball
  • Set of brass gauge glass fixtures with 10-3/4" gauge glass
  • Pump option: Burks 20CS6M single-phase pump or Burks 320CS6M three-phase pump
  • 2 HP, 3500 RPM turbine pump package
  • Factory plumbing including pipe nipples, gate valve, strainer, union, and boiler drain; plumbed and ready to install
  • Need tank-only replacement later? View the matching 18 x 48 vertical steel replacement return tank

Best Fit Applications

This system is built for larger boiler rooms, mechanical spaces where a vertical receiver layout is preferred, and installations that need added condensate storage without spreading the footprint wider.

The 40–50 HP sizing range makes this a practical option for boiler applications needing larger receiver volume and stronger pump capacity than the smaller vertical systems while maintaining a manageable floor footprint.

For larger systems or different construction options, browse our full line of condensate return systems, the matching 18 x 48 vertical replacement return tank, and custom steam equipment.

BJHV-7 Specifications

Model BJHV-7
Boiler Horsepower Range 40–50 HP
Tank Orientation Vertical
Tank Diameter 18"
Tank Height 48"
Tank Capacity 52 Gallons
Tank Material 11 Gauge Steel
Pump Options Burks 20CS6M or Burks 320CS6M
Pump Horsepower 2 HP
Phase Options Single Phase or Three Phase
Pump Speed 3500 RPM
Float Assembly Options 1/2" or 3/4" float assembly
Float Components Brass float valve, brass rod, 5" copper float ball
Gauge Glass 10-3/4" gauge glass with brass fixtures
Factory Plumbing Included Pipe nipples, gate valve, strainer, union, boiler drain; plumbed and ready to install

Pump, Tank & Service Support

This system can be configured with the Burks 20CS6M single-phase pump or the Burks 320CS6M three-phase pump.

For repair and maintenance support, browse our pump parts and return tank parts.

Need tank-only replacement options? View the matching 18 x 48 vertical steel replacement return tank.

Built for Larger Vertical Boiler Feed Applications

The BJHV-7 is a vertical 11 gauge steel condensate return system in the Rema Dri-Vac line, making it a practical choice where larger receiver volume and stronger pump capacity are needed without increasing the system footprint wider. It uses the Burks 20CS6M or 320CS6M pump package with an 18" x 48" vertical steel receiver for 40–50 HP boiler applications.

If the system remains in service but the tank needs replacement later, the matching 18 x 48 vertical replacement return tank provides a direct tank-only option.

For a broader overview of system function, construction options, and sizing direction, visit our condensate return systems overview page.

Frequently Asked Questions

What boiler size is the BJHV-7 designed for?

The BJHV-7 is designed for boiler applications in the 40 to 50 boiler horsepower range.

What pump comes with the BJHV-7 system?

This system can be configured with either the Burks 20CS6M single-phase pump or the Burks 320CS6M three-phase pump. Both are 2 HP, 3500 RPM turbine pump packages.

What tank size is used on the BJHV-7?

The BJHV-7 uses an 18" diameter x 48" high vertical 11 gauge steel receiver tank with approximately 52 gallons of capacity.

Can I buy the tank separately later?

Yes. The matching tank-only replacement is the 18 x 48 vertical steel replacement return tank.

What is included with the BJHV-7 condensate return system?

The system includes the vertical receiver tank, mounted stand, float assembly, brass float valve, brass rod, 5" copper float ball, brass gauge glass fixtures with 10-3/4" gauge glass, the pump package, and factory plumbing including pipe nipples, gate valve, strainer, union, and boiler drain.

Additional information

Water Inlet

1/2", 3/4"

Single Phase or Three Phase Pump

Single, Three